GEM 400B+
Intelligent, Smart, and Clinical
Micro-controller Design
PPREM technology (Pad Patient Return Electrode Monitoring)
Surgical Assistance (10 Programs)
Error Indication (Displays error messages on the display)
Endo Cut (Pulse Cut)
Four Bipolar Modes with Bipolar CUT, Max. power of 150 W
Four Monopolar CUT modes, Max. power of 400 W
Four Monopolar COAG modes, Max. power of 150 W
Separate Display for Monopolar CUT, COAG, and BIPOLAR
Separate Footswitch for Unipolar and Bipolar
ESU Applications: | ||
• Gynecology • Urology( TURP ) • Laproscopic Surgeries • Endoscopy ( ERCP ) |
• Oncosurgery • Heart & Chest surgery • Neurosurgery |
• Spine • Arthroscopy • All other general surgical procedures |
Technical Specifications |
|
Monopolar CUT | |
LOW | 480 Khz sinusoid with low max. voltage, 300 W @ 300 E |
PURE CUT | 480 Khz sinusoid, 400 W @ 300 E |
BLEND1 | 480 Khz sinusoid with 70% duty cycle, 250 W @ 300 E |
BLEND2 | 480 Khz sinusoid with 55% duty cycle, 200 W @ 300 E |
Monopolar COAG | |
SPRAY | 480Khz sinusoid bursts, 120 W @ 500 E |
FULGURATE1 | 480Khz damped sinusoid bursts, 150 W @ 500 E |
FULGURATE2 | 480Khz damped sinusoid bursts, 150 W @ 500 E |
DESICCATE | 480 Khz sinusoid with very low max. voltage, 80 W @ 500 E |
BIPOLAR | |
MICRO | 480 Khz sinusoid with lower output voltage, 80 W @ 100 E |
MACRO | 480 Khz sinusoid with higher output voltage, 80 W @ 100 E |
STANDARD | 480 Khz sinusoid with medium output voltage, 80 W @ 100 E |
CUT | 480 Khz sinusoid with high output voltage, 150 W @ 100 E |
Patient Electrode monitoring System (Resistance range) | Dual area PREM patient return Electrode: 10 – 135 ohms |
Single Patient Return electrode: < 20 ohms | |
Power Deviation | less than 15% or 5 watts, whichever is greater |
Dimensions(L X W X H) | 400 x 330 x 120 mm |
Weight | < 7 kg |
Power supply | 180 – 270 Vac , 50/60 Hz |
Max. Power Input | 1000VA, Fuse : 5A |
Standard Accessories: | Optional Accessories: | |
• Monopolar handle with silicon cable with electrode set • Bipolar forcep with silicon bipolar cable • Silicon patient plate with cable • Double Pedal Footswitch • Disposable Hand switch • Mains cord • Unit Cover |
• Reusable Hand switch • Bionet Bipolar forcep • Long 9” Bipolar forcep • Small 4” Bipolar forcep • Angled tip Bipolar forcep • Monopolar forcep with cable |
GEM 300
Intelligent, Smart, and Clinical
Micro-controller Design
PPREM technology (Pad Patient Return Electrode Monitoring)
Surgical Assistance (10 Programs)
Error Indication (Displays error messages on the display)
Endo Cut (Pulse Cut)
Three Bipolar Modes with Bipolar CUT, Max. power of 150 W
Three Monopolar CUT modes, Max. power of 300 W
Three Monopolar COAG modes, Max. power of 150 W
Separate Display for Monopolar CUT, COAG, and BIPOLAR
Separate Footswitch for Unipolar and Bipolar
ESU Applications: | ||
• Gynecology • Urology( TURP ) • Laproscopic Surgeries • Endoscopy ( ERCP ) |
• Oncosurgery • Heart & Chest surgery • Neurosurgery |
• Spine • Arthroscopy • All other general surgical procedures |
Technical Specifications |
|
Monopolar CUT | |
PURE CUT | 480 Khz sinusoid, 300 W @ 300 E |
BLEND1 | 480 Khz sinusoid with 70% duty cycle, 250 W @ 300 E |
BLEND2 | 480 Khz sinusoid with 55% duty cycle, 200 W @ 300 E |
Monopolar COAG | |
SPRAY | 480Khz sinusoid bursts, 120 W @ 500 E |
FULGURATE | 480Khz damped sinusoid bursts, 150 W @ 500 E |
DESICCATE | 480 Khz sinusoid with very low max. voltage, 80 W @ 500 E |
BIPOLAR | |
MICRO | 480 Khz sinusoid with lower output voltage, 80 W @ 100 E |
MACRO | 480 Khz sinusoid with higher output voltage, 80 W @ 100 E |
CUT | 480 Khz sinusoid with high output voltage, 150 W @ 100 E |
Patient Electrode monitoring System (Resistance range) | Dual area PREM patient return Electrode: 10 – 135 ohms |
Single Patient Return electrode: < 20 ohms | |
Power Deviation | less than 15% or 5 watts, whichever is greater |
Dimensions(L X W X H) | 400 x 330 x 120 mm |
Weight | < 7 kg |
Power supply | 180 – 270 Vac , 50/60 Hz |
Max. Power Input | 1000VA, Fuse : 5A |
Standard Accessories: | Optional Accessories: | |
• Monopolar handle with silicon cable with electrode set • Bipolar forcep with silicon bipolar cable • Silicon patient plate with cable • Double Pedal Footswitch • Disposable Hand switch • Mains cord • Unit Cover |
• Reusable Hand switch • Bionet Bipolar forcep • Long 9” Bipolar forcep • Small 4” Bipolar forcep • Angled tip Bipolar forcep • Monopolar forcep with cable |
GEM 200
 Combo unit of ESU and Vessel Sealer
 Intelligent, Smart, and Clinical
 Micro-controller design
 PPREM technology (Pad Patient Return Electrode Monitoring)
 Surgical Assistance (99 Programs)
 Error Indication
 Endo Cut (Pulse Cut)
 Bipolar Sealing (150w)
 Four Bipolar Modes, Max. power of 150 W
 Four Unipolar CUT modes, Max. power of 300 W
 Four Unipolar COAG modes, Max. power of 150 W
 Auto stops the RF energy upon completion of Seal
 Separate Footswitch for Unipolar and Bipolar
 With Bi-Clamp for Open surgery
 Optional Disposable/Reusable Laparoscopic attachments
ESU Applications: | ||
• Gynecology • Endoscopy ( ERCP ) • Oncosurgery |
• Heart & Chest surgery • Neurosurgery • Spine |
• Arthroscopy • All other general surgical procedures |
Technical Specifications |
|
Monopolar CUT | |
PURE CUT | 480 Khz sinusoid, 200 W @ 300 E |
BLEND1 | 480 Khz sinusoid with 70% duty cycle, 150 W @ 300 E |
BLEND2 | 480 Khz sinusoid with 55% duty cycle, 120 W @ 300 E |
Monopolar COAG | |
SPRAY | 480Khz sinusoid bursts, 120 W @ 500 E |
FULGURATE | 480Khz damped sinusoid bursts, 150 W @ 500 E |
DESICCATE | 480 Khz sinusoid with very low max. voltage, 80 W @ 500 E |
BIPOLAR | |
COAG | 480 Khz sinusoid with lower output voltage, 80 W @ 100 E |
CUT | 480 Khz sinusoid with high output voltage, 150 W @ 100 E |
Patient Electrode monitoring System (Resistance range) | Dual area PREM patient return Electrode: 10 – 135 ohms |
Single Patient Return electrode: < 20 ohms | |
Power Deviation | less than 15% or 5 watts, whichever is greater |
Dimensions(L X W X H) | 400 x 330 x 120 mm |
Weight | < 7 kg |
Power supply | 180 – 270 Vac , 50/60 Hz |
Max. Power Input | 1000VA, Fuse : 5A |
Standard Accessories: | Optional Accessories: | |
• Monopolar handle with silicon cable with electrode set • Bipolar forcep with silicon bipolar cable • Silicon patient plate with cable • Double Pedal Footswitch • Disposable Hand switch • Mains cord • Unit Cover |
• Reusable Hand switch • Bionet Bipolar forcep • Long 9” Bipolar forcep • Small 4” Bipolar forcep • Angled tip Bipolar forcep • Monopolar forcep with cable |
Intelligent, Smart and Clinical
GEM series of advanced powerful microcontroller based surgical generators gives the surgeon a powerful tool to deliver selected power over varying tissue types. Hence, no need of high power settings and more energy which in turn reduces tissue damage.
- Less thermal damage
- Less charring and sparking
- Reduces recovery time
Micro-controller design
GEM series of generators use a single advanced and powerful controller which controls, senses, and acts upon feedback by continuously monitoring voltage, current, tissue impedance, RF leakage, Power.
- Single advanced and powerful controller.
- Power micro-controller with minimum reaction time and maximum processing speed
- High power efficiency
- Minimizes tissue damage
- Enhanced performance at low power settings which in turn minimizes neuro-muscular stimulation
Surgical Assistance
- User – settable and pre-programmed programs to assist in easy and fast use of the system
- Select the desired program using the program key and the system is ready for use with only one key touch
- Separate program display to avoid confusion with power and modes
Error Indicator
- Performs a self test during switch ON to check system status and resumes in the last used program and modes
- Displays error messages on the display depending upon the faults diagnosed
- Example: Displays error message on display to indicate patient return electrode error” P ERROR”
PPREM
Pad-Patient Return Electrode Monitoring eliminates the risk of patient burns at return electrode site. Pad-patient impedance monitoring using a dual area patient return electrode.
- Audio visual alarm
- Error message on display
- Deactivates the RF to ensure safe operation
Endo cut (Pulse cut)
Endo cut is cutting power delivered in bursts (in seconds) useful in Endo surgeries like papillotomy and polypectomy.
- Three different burst duration in seconds (Two, Three and Four seconds)
Bipolar Sealing
- Optimized combination of pressure and energy creates the seal by melting the collagen & elastin in the vessel wall & reforming it in to a seal & results in no sticking or charring
- Feed back controlled response system automatically discontinues energy delivery when the seal cycle is complete
- High strength seal, Minimal collateral RF thermal effect to adjacent tissue
Modes | |
 CUT |  Provides uniform cutting through all types of tissues. |
 LOW |  Provides precise cutting with lower max. voltage which ensures minimum collateral tissue damage suitable for Neuro, Plastic, ENT. |
 PURE CUT |  Provides pure, precise cutting with higher max. voltage suitable for TURP |
 BLEND |  Provides CUT power with useful coagulation (cutting with different levels of haemostasis ) to reduce bleeding |
 COAG |  Satisfies all coagulation needs of the surgeons |
 SPRAY |  Non contact coagulation with minimal depth of necrosis |
 FULGURATE 1 |  Provides coagulation with lower max. voltage |
 FULGURATE 2 |  Provides essential coagulation with high max. voltage with high crest factor |
 DESICCATE |  Provides low voltage contact coagulation suitable for delicate work |
 BIPOLAR |  Provides precise bipolar coagulation effect |
 MICRO |  Precise performance with minimum collateral tissue damage |
 MACRO |  Provides precise performance with higher maximum voltage |
 STANDARD |  Provides precise performance, suitable for most applications |
 BI CUT |  Provides Cutting effect in bipolar using suitable instrument |
 BI SEAL |  Provides intelligent sealing capabilities to the user upto 7 mm using Open and Lapro attachments, Audio and output cutoff and upon Seal |
SSEG 302
 Fully Solid State design
 Independent Monopolar isolated outputs
 The monopolar generator provides CUT, BLEND1, BLEND2 and SPRAY, FULGURATE, DESICCATE COAGULATION facilities
 Operating mode are identified by audio tones and Panel light
 Illuminated ON/OFF switch
 Patient plate monitoring circuit
 Natural convection cooling with silent operation
 Bipolar generator with 3 modes
Applications: |
• For all types of minor/major surgeries including under water cutting T.U.R. and for Bipolar micro coagulation. |
Technical Specifications |
|
 Monopolar CUT | |
 PURE CUT |  400 ± 25 W, 500 ohms load |
 BLEND1 |  250 ± 15 W, 500 ohms load |
 BLEND2 |  200 ± 15 W, 500 ohms load |
 Monopolar COAG | |
 SPRAY |  120 ± 10 W, 300 ohms load |
 FULGURATE |  150 ± 15 W, 300 ohms load |
 DESICCATE |  80 ± 10 W, 300 ohms load |
 BIPOLAR | |
 MICRO |  80 ± 10 W, 125 ohms load |
 MACRO |  80 ± 10W, 125 ohms load |
 CUT |  100 ± 10 W, 300 ohms load |
Output Frequency |  Frequency 500 ± 25 Khz |
 Power |  220-240 Vac ± 5%, 50/60 Hz |
 Dimensions(L X W X H) |  400 x 310 x 140 mm |
 Weight |  < 8kg |
Standard Accessories: | Optional Accessories: | |
• Monopolar handle with silicon cable with electrode set • Bipolar forcep with silicon bipolar cable • Patient Plate with cable • Double Pedal Footswitch • Mains cord • Unit Cover |
• Monopolar forceps with cord and jack • S.S. Paediatric Patient plate with cable • Silicon patient plate with cable • Servo controlled voltage stabilizer • Pencil hand switch ( Disposable / Reusable ) |
SSEG 300B
 Fully Solid State design
 Independent Monopolar isolated outputs
 The monopolar generator provides CUT, BLEND, and COAGULATION facilities.
 Operating mode are identified by audio tones and Panel light
 Illuminated ON/OFF switch
 Patient plate monitoring circuit
 Audio-visual indication for patient plate lead faults
 Natural convection cooling with silent operation
 Bipolar generator has footswitch control
Applications: |
• For all types of minor/major general surgeries and Bipolar micro coagulation. |
Technical Specifications |
|
 Monopolar CUT | |
 PURE CUT |  300 ± 25 W, 500 ohms load |
 BLEND 1 |  200 ± 15 W, 500 ohms load |
 BLEND 2 |  200 ± 15 W, 500 ohms load |
 Monopolar COAG | |
 SPRAY |  120 ± 15 W, 300 ohms load |
 FULGURATE |  150 ± 15 W, 300 ohms load |
 DESICCATE |  80 ± 15 W, 300 ohms load |
 BIPOLAR | |
 MICRO |  80 ± 10W, 125 ohms load |
 MACRO |  80 ± 10W, 125 ohms load |
 CUT |  100 ± 10W, 300 ohms load |
Output Frequency |  Frequency 500 ± 25 Khz |
 Power |  220-240 Vac ± 5%, 50/60 Hz |
 Dimensions(L X W X H) |  400 x 310 x 140 mm |
 Weight |  <8 kgs |
Standard Accessories: | Optional Accessories: | |
• Monopolar handle with silicon cable with electrode set • Bipolar forcep with silicon bipolar cable • Patient Plate with cable • Double Pedal Footswitch • Mains cord • Unit Cover |
• Monopolar forceps with cord and jack • S.S. Paediatric Patient plate with cable • Silicon patient plate with cable • Servo controlled voltage stabilizer • Pencil hand switch ( Disposable / Reusable ) |
SSEG 402
 Fully Solid State design
 The monopolar generator provides CUT and COAGULATION facilities
 Operating mode are identified by audio tones
 Illuminated ON/OFF switch
 Patient plate monitoring circuit
 Audio indication for patient plate lead faults
 Fan cooling with silent operation
 Bipolar has CUT as well COAG
Applications: |
• For all types of general surgeries and Bipolar cutting and coagulation. |
Technical Specifications |
|
 Monopolar CUT | |
 PURE CUT |  200 ± 25 W, 500 ohms load |
 Monopolar COAG | |
 COAG |  120 ± 15 W, 300 ohms load |
 BIPOLAR | |
 COAG |  80 ± 10W, 125 ohms load |
 CUT |  80 ± 10W, 125 ohms load |
Output Frequency |  Frequency 500 ± 25 Khz |
 Power |  220-240 Vac ± 5%, 50/60 Hz |
 Dimensions(L X W X H) |  270 x 245 x 130 mm |
 Weight |  7 kg |
Standard Accessories: | Optional Accessories: | |
• Monopolar handle with silicon cable with electrode set • Bipolar forcep with silicon bipolar cable • Patient Plate with cable • Double Pedal Footswitch • Mains cord • Unit Cover |
• Monopolar forceps with cord and jack • S.S. Paediatric Patient plate with cable • Silicon patient plate with cable • Servo controlled voltage stabilizer • Pencil hand switch ( Disposable / Reusable ) |
SSEG 502
 Fully Solid State design
 Generator provides CUT and COAGULATION facilities
 Operating mode are identified by audio-visual tones
 Illuminated ON/OFF switch
 Auto Bipolar facility
 Natural convection cooling with silent operation
Applications: |
• For all types of general surgeries and Bipolar cutting and coagulation. |
Technical Specifications |
|
 BIPOLAR CUT | |
 PURE CUT |  80 ± 10 W, 125 ohms load |
 BIPOLAR COAG | |
 COAG |  80 ± 10 W, 125 ohms load |
 AUTO |  80 ± 10 W, 125 ohms load |
 Output Frequency |  Frequency 500 ± 25 Khz |
 Power |  220-240 Vac ± 5%, 50/60 Hz |
 Dimensions(L X W X H) |  260 x 210 x 120 mm |
 Weight |  5 kg |
Standard Accessories: |
• Bipolar forcep with silicon bipolar cable • Double Pedal Footswitch • Mains cord • Unit Cover |
The GALVOTOM is a modern solid-state electrosurgical unit. Both in design and equipment it meets all the requirements of electrosurgery. High Power and various modes make it ideal for general & clinical practice.
The GALVOTOM SSEG has separate controls for cutting, coagulation, bipolar microcoagulation. It offers all the advantages of electrosurgery: simplified haemostasis (Blend control) with hand as well as foot control.
Its output makes it suitable for procedures in E.N.T., Gynecology, Neurosurgery, Orthopedic, General surgery, Plastic surgeries, Laproscopic Interventions, Including Urological and Thoracic procedures. Can be used for all major and minor operations. Its compact size and light weight makes it a best option for various fields.
VASCULAR DOPPLERÂ It is used by Urologists, Plastic Surgeons, Ortho Surgeons, Vascular Surgeons etc. It is most portable, handy unit. It has facility of mains as well as operates on batteries. |
Applications: | |
For routine screening to… • Cerebral – vascular insufficiency • In case of Transient Ischemic Attack (TIA) • Detection of Arteriosclerosis • Blood flow monitoring in suspected cases of internal carotid stenosis and arterial injuries |
• Thrombophlebitis and venous thrombosis which may lead to pulmonary embolism • Acute varicose veins, occlusive vascular and arterial diseases • Early detection of limb loss in case of gangrene or diabetes • To distinguish between epididymitis and torsion • Post-surgical monitoring of grafted or reconstructed segments |
Technical Specifications |
 Frequency |  8 MHZ |
 Power Supply |  KSV X 6 Batteries |
 Size |  6″ X 6″ X 3″ |
 Weight |  2.2 kg |
Standard Accessories: |
• 8 MHZ Transducer Probe • 9 V Mains Adapter • Oil Bottle • Carrying Care |
HALOGEN SPOT LIGHT
 MODEL : 12V, 50W
 Useful in Surgery, Gynaecology, ENT and Dermatology
 Variable regulator to control intensity
 Pedestal (Floor) as well as wall mounted models
 Light intensity of 1250 foot candles at 16 in. diameter
 Light temp. is kept at 3400 Kelvin to enable identification of true tissue color
 Adjustable in Any direction, angle and height
 Extremely Compact and light weight
 Source gun is Detachable
 Easy to Dismantle and Reassemble
 Ideal for Labour room, OPD and Examination
Suitable for Examination in Labour Room/OPD or in Operation theatre if additional light is required. Single 15w Power LED Module, hence low power consumption. Sleek Design. Also available Wall Mount Clamp (optional) for wall mounting the light.
• Light Intensity is adjustable
• White light, No Heat
• Flexible Gooseneck for Positioning
• Life more than 50000hrs
• Input Supply : 180 – 270Vac
• Mobile on Wheels, Sleek Design
• SS stand, Height Adjustable
• Lux more than 50000
• Colour temp 5500k