SKIN CAUTERY : MODEL GYFRECATOR G101
The Gyfrecator allows precise destruction of all types of cutaneous lesion (both superficial and deep) and controls surgical bleeding simply, quickly and effectively. Bleeding can prolong even minor procedures and increase the risk of haematoma formation, infection and wound dehiscence that may lead to poor cosmetic results.The Gyfrecator is widely used for outpatient procedures that range from epilation to vasectomy.
It is commonly used by Dermatologists in conjunction with curettage for the destruction of small well-defined skin cancers such as basal cell carcinoma and for the treatment of a wide variety of cutaneous lesions.
The GEMI GYFRECATOR lets you perform a wide variety of desiccation, fulguration and coagulation procedures. The Gyfrecator is a Surgical Diathermy Unit. It produces a controlled electrical discharge of high frequency and high voltage, which selectively destroys tissue by the passage of electric current. |
Applications: | |
• Dermatology: Benign and Malignant Lesions • Plastic Surgery: Hemostasis • Proctology: Fissure-in-ano, Hemmorrhoids • Gynecology: Vaginal Cysts,Cervicitis, Pruritus Vulvae, Skene’s Glands, Urethral Tumors |
• Ophthalmology: Burn Entropian, Chalazion • Urology: Bladder, Vasectomy, Venereal Warts • Otolaryngology: Adenoid, Tonsil, Nasal Polyps • Dental/Oral Surgery: Apicoectomy, Gingivectomy, Dentin Desensit • Urology/ Ophthalmology /General Family Practice |
Technical Specifications |
Power supply | 220-240 VAC. 50/60 Hz |
Power output | 50 watts Approx |
Dimension | 197 x 175 x 70 mm |
Weight | less than 3 kgs |
Standard Accessories: | Optional Accessories: |
• Cautery handle with Autoclaveable Silicon Cable • Set of five electrodes • Footswitch • Power cord • Carrying case |
• Inactive plate (SS) with cable |
RADIO FREQUENCY UNIT
The Technique of Radio Surgery involves the passage of high frequency radio waves(2Mhz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, an results in cellular molecular dissolution of individual tissue cells.
High frequency radio surgery unit consists of monopolar cutting, Coagulation and Bipolar modes to treat wide variety of skin disorders with excellent cosmetic effects.
Minimum blood loss and pain, Relaxed and easy to use, Minimum heat without charring are some of the features of the Radio Frequency unit.
Technical Specifications |
Input | 220-240 vac, 50/60 Hz | ||||
Frequency | 2 Mhz | ||||
Outputs |
|
||||
Weight | < 3.5 kgs | ||||
Dimensions | 258 x 190 x 82 mm |
Standard Accessories: |
• Monopolar handle with silicon autoclaveable cable • Electrode set • SS patient plate with cable • Single Pedal Footswitch • Unit cover • Mains cord |
RADIO FREQUENCY UNIT RF-2HF
The Technique of Radio Surgery involves the passage of high frequency radio waves(2Mhz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to these radio waves causes the cellular water in the soft tissue to heat, which produces steam, an results in cellular molecular dissolution of individual tissue cells.
High frequency radio surgery unit consists of monopolar cutting, Coagulation and Bipolar modes to treat wide variety of skin disorders with excellent cosmetic effects.
Minimum blood loss and pain, Relaxed and easy to use, Minimum heat without charring are some of the features of the Radio Frequency unit.
Works on Handswitch as well as Footswitch
Technical Specifications |
Input | 220-240 vac, 50/60 Hz | ||||
Frequency | 2 Mhz | ||||
Outputs |
|
||||
Weight | < 3.5 kgs | ||||
Dimensions | 258 x 190 x 82 mm |
Standard Accessories: |
• Active handle with Silicon cable • Electrode set • Patient plate with cable • Bipolar Silicon cable with Forcep • Disposable Handswitch • Power cord • Carrying case • Operating manual |
WOODS LAMP
Woods Lamp comes with twin UV tubes to induce fluoresence in Dermatoses and an additional extra white tube for magnification. Both the lights can be operated seperately. Examination of skin or hair with the Woods Lamp is a time trusted technique to aid in the clinical diagnosis of some cutaneous disorders.
Woods Lamp is an inexpensive and essential equipment. Woods light examination should be performed in a dark room, and total darkness is also satisfactory.The UV light tubes are commercially available and the emitted light is of lesser intensity (longer wave length) than the light absorbed.
Following are the indications in Dermatology:
Dermatoses in the intertrignious areas
Patches on the scalp with scaling or partial hair loss(especially with broken hairs)
Pigmentary alterations
Diagnosis of burrows in scabies
Blisters and punctuate erosions on the dorsum of hands and forearms
Tinea versicolor
SSEG 302
Made with high quality hypodermic needles – ensures smooth flow of cryogenic gas and last longerEquipped with specially designed 'Silencer' – Enables quieter operation
Body made of ABS plastic, in attractive colors –aesthetically appealing
Specially designed probes for different specific end uses- enables wide usage of same instrument for different specialties
Attractive light-weight carrying case–easy portability
Hand Operated
Uses Nitrous Oxide (N2O) or Carbon dioxide (CO2)
Interchangeable probe facility available
A combined unit for Gynaecology, General Surgery, E.N.T and Dermatological applications with any one probe attached to it
Spare Washers and carrying case
Standard unit is supplied with 1 probe
Probes Available: |
ULTRASOUND THERAPY UNIT
(MODEL: ULT10)
Micro-controller based, Feather Touch, Digital System
Uses of ultrasound include facial and body skin rejuvenating treatments, reduction of stretch marks, treatment of contracture and scar tissue such as around breast implants, and the pre- and post-operative treatment of plastic surgery patients to accelerate healing and recovery after procedures such as face lifts, tummy tuck, and liposuction.
Built in 2 line LCD module with backlight
Menu includes continuous mode and pulse mode with
3:4, 2:3, 1:2, 1:4, 1:8, 1:12
42 programs
Computerized panel design with soft touch switches for comfort in operation
User friendly, simple and easy to operate
Built in clinical programs
Technical Specifications |
Display | 16 X 2 LCD |
Output Timer | 2.5 W/cm2 |
Input Supply | 230 VAC, 50 Hz |
Modes | Continuous, Pulse Modes |
Frequency | 1Mhz |
Pulse Frequency | 8, 48, 100Hz |
Duty Cycle | 10, 20, 50% |
Timer | 0 – 30 MIN |
Dimension | 275 x 200 x 85 mm |
Standard Accessories: |
• Light Weight Sound Head with Cable • Supplied with Carrying Case and gel bottle |
BODY SHAPE – SLIMMER
Available models: 8 pads unit, 16 pad unit and 24 pad unit
BODY SHAPE is a revolutionary new product, especially designed for professional and personal use in clinics, gyms, hospitals and at home, giving relaxing and pleasant treatment for a dream figure. It is effortless and time saving method to give exercise to your muscles in a smooth and safe way, which is called a “passive exercise“.
The unit has a versatile treatment selection. It has 13(Thirteen) programs to select from, which are INCH LOSS, FAT LOSS, LIFTING, TONING, RESHAPING, MASSAGING, RELIEF, FIRMING, ALL MODE AND THREE TENS PROGRAMS FOR PAIN RELIEF.
Micro-controller based
4 line LCD display
Shockproof and Elegant ABS cabinet
Light weight, compact and easy to use
Feather touch Keypad
Separate intensity controls for all channels
Treatment Timer
Technical Specifications |
Power supply | 230VAC, 50 Hz |
Wave Shape | Biphasic |
No. of Channels | 04 / 08 / 12 |
No. of Pads | 8 / 16 / 24 |
Output Voltage | 100V peak to peak (max.) |
Display | 20 X 4 LCD Display (Blue background & white text) |
PROGRAMS | 13 ( THIRTEEN ) |
Timer | 0 – 99 min |
Size | 275 x 200 x 85mm |